Are you stuck with an error message saying “PI point cannot be found” when trying to create an attribute from analyses in PI System Explorer? Don’t worry, you’re not alone! This article will guide you through the steps to troubleshoot and resolve this issue, so you can get back to creating powerful attributes in no time.

Understanding the Error Message

Before we dive into the solution, let’s understand what’s happening behind the scenes. When you try to create an attribute from an analysis in PI System Explorer, it attempts to reference a PI point that’s supposed to be associated with the analysis. However, if the PI point is missing or not properly configured, you’ll encounter the “PI point cannot be found” error.

Causes of the Error

There are a few reasons why you might see this error message:

  • The PI point is not created or configured correctly.
  • The analysis is not correctly linked to the PI point.
  • The PI point is not available in the current context or AF database.

Step-by-Step Troubleshooting Guide

Fear not, dear reader! Follow these steps to identify and fix the issue:

Step 1: Verify PI Point Existence

Open PI System Explorer and navigate to the AF database where your analysis is located. Check if the PI point exists by searching for it in the PI Point Explorer:


[AF Database] > PI Points > Search

If the PI point doesn’t exist, create it using the PI Point Editor:


[AF Database] > PI Points > New PI Point

Step 2: Check PI Point Configuration

Ensure the PI point is properly configured:

  • Verify the PI point’s data type matches the analysis output.
  • Check the PI point’s scan class and compression settings.
  • Make sure the PI point is not disabled or in an error state.

Step 3: Verify Analysis to PI Point Linkage

Confirm that the analysis is correctly linked to the PI point:


[AF Database] > Analyses > [Your Analysis] > Configuration

In the analysis configuration, check the “Output” section and ensure the correct PI point is selected:

Field Value
Output [Your PI Point]

Step 4: Check AF Database Context

Verify that you’re working in the correct AF database and context:


[AF Database] > [Your AF Database]

Make sure you have the necessary permissions and access to the AF database and PI points.

Step 5: Restart PI System Explorer

Sometimes, a simple restart can resolve the issue. Close and reopen PI System Explorer to ensure any changes take effect.

Solution Implementations

Now that we’ve troubleshooted the issue, let’s implement the solutions:

Creating a New PI Point

Follow these steps to create a new PI point:

  1. Navigate to the PI Point Explorer.
  2. Right-click and select “New PI Point” or use the shortcut “Ctrl + Shift + N”.
  3. Enter the necessary information, such as the PI point name, data type, and scan class.
  4. Click “OK” to create the PI point.

Linking the Analysis to the PI Point

Follow these steps to link the analysis to the PI point:

  1. Navigate to the analysis configuration.
  2. In the “Output” section, select the correct PI point from the dropdown list.
  3. Click “OK” to save the changes.

Conclusion

By following these steps, you should be able to resolve the “PI point cannot be found” error and successfully create an attribute from an analysis in PI System Explorer. Remember to double-check your PI point configuration, analysis linkage, and AF database context to avoid any future issues.

If you’re still experiencing problems, feel free to reach out to your PI System administrator or OSIsoft support for further assistance.

Happy troubleshooting!

Frequently Asked Question

Got stuck with the “PI System Explorer attribute created from Analyses: Pi point cannot be found” error? Don’t worry, we’ve got you covered! Check out these FAQs to troubleshoot the issue.

What does the “Pi point cannot be found” error mean in PI System Explorer?

This error occurs when the PI System Explorer is unable to locate the PI point associated with an attribute created from an analysis. It might be due to the PI point not existing, being deleted, or having incorrect settings.

How do I verify if the PI point exists in the PI Data Archive?

You can use the PI System Explorer to search for the PI point by its name or tag. If the point doesn’t exist, you can create a new one or check if it’s been renamed or moved to a different AF element.

What if the PI point exists, but the error persists?

Check the PI point’s data type and settings to ensure they match the analysis output. Also, verify that the analysis is properly configured and running without errors. If you’re still stuck, try recreating the attribute or seeking help from a PI System admin.

Can I troubleshoot the issue using PI Message Logs?

Yes, you can! Check the PI Message Logs for error messages related to the analysis or PI point. This will help you identify any underlying issues or configuration problems that might be causing the error.

What if none of the above steps resolve the issue?

Don’t worry! You can reach out to OSIsoft support or a PI System expert for further assistance. They’ll help you dive deeper into the issue and find a solution.